  Datasheet File OCR Text:
 CT2100-400 MICROPROCESSOR CONTROLLED QUAD SOLID STATE RELAY
Features * 4 Independent 1.0 Amp Switches CIRCUIT TECHNOLOGY * 600 Volts Isolation between Switches www.aeroflex.com/act1.htm * Operates from a 5 Volt Logic and 15 Volt Bias * D.C. Trip Level 1.3 Amps * Switches are Designed to withstand Electro-Magnetic Pulse (EMP) * Functions and Operates from -55C to +125C in Military Environments * Processed and Screened to Mil-STD-883 Specifications
The CT2100-400 is a microprocessor controlled, quad solid state relay that incorporates fully isolated switch control and built-in test. The hybrid provides 600 Volts isolation between control inputs and switch outputs. Internal control and status registers provide analog switch function which operates via simple I/O commands.
Block Diagram
4
PRESET/CLEAR1-4 WRITE INIT
4 4
Smart Switch 1
S1+
Switch Control Latch 600 Volt Isolation
CS A0 A1
TRIP S1-
Sense DATA0-7 8 Bit 2
8
ON/OFF & TRIP
8
ON/OFF and TRIP Switch Status
Smart Switch 2
S2+ S2- S3+ S3- S4+ S4-
READ Smart Switch 3
Smart Switch 4
eroflex Circuit Technology - SCDCT2100 REV B 10/1/98
DESCRIPTION
The CT2100-400 is a quad solid state relay. The device has been designed to provide an interface which operates as a simple computer I/O port. The switches are controlled by a single data word which the processor writes to an internal control latch. In addition to the basic switch function ON/OFF and Trip flags provide the operational status of each of the four switches. These signals are internally contained in an 8 bit status register which is accessible by an I/O read command. The switches may also be controlled asynchronously (without write strobes) by use of separate initialization pins. These may also be used for Power-Up control in a microprocessor based system. The CT2100-400 has four independent fully isolated switches which may be used as high side or low side drivers. The isolated design allows the user to parallel devices or place them in series as required for the specific application. Control of the switch is via I/O write (Address 0) or asynchronous control lines. The CT2100-400 has an internal switch control latch which is updated via subsystem I/O write as illustrated in Figure 2. Once the I/O write is completed the switch is latched into the OFF or ON state. The switch may also be controlled via individual PRESET and CLEAR lines. These lines asynchronously drive the switch control latch without the need for a write
strobe. The PRESET/CLEAR inputs are enabled by the initialize pin.
SWITCH STATUS
Each switch in the CT2100-400 is monitored for circuit Trip and ON/OFF. This data is contained in a 8 bit status register which is accessible via an I/O read (Address 0) command. The timing for the I/O read is shown in Figure 1. The Trip and ON/OFF flags are provided to the system to assess the operational capability of the switch versus the status of the controlled load. The Trip bit is set high when the switch has conducted between 1.1 to 3 amps of current based on the time to trip curve in Figure 3. The over current DC trip point is typically 1.3 amps.
SWITCH CONTROL
Table 1 -- Absolute Maximum Ratings
Supply Voltage (VCC) -- Pin 20 Supply Voltage (VEE) -- Pin 1 Logic Input Voltage -- Pins 2-9, 12-19 Switch Point Voltage -- Pins 39-40, 29-32, 21-22 Storage Temperature Range -0.5 to +7.0 Volts DC -.5 to +18 Volts DC -0.5 to VCC +.5 Volts DC -600 to +600 Volts (200 ns) 80 Volts DC -65C to +150 C
Table 2 -- Recommended Operating Conditions
Supply Voltage (VCC) -- Pin 20 Supply Voltage (VEE) -- Pin 1 Logic Input Maximum Voltage (High) -- Pins 2-9, 12-19 Logic Input Minimum Voltage (Low) -- Pins 2-9, 12-19 Switch Point Voltage -- Pins 39-40, 29-32, 21-22 Operating Temperature Range
2
+5.0 VDC 10% +14.25 to +15.75 VDC +3.3 V +0.8 V 60 VDC -55C to +125 C
Aeroflex Circuit Technology
SCDCT2100 REV B 10/1/98 Plainview NY (516) 694-6700
Timing Waveforms
Th VALID Tsu WRITE/ CS Tpw READ/ CS Tpw STATUS DATA Td VALID Th
SWITCH CONTROL DATA
Figure 1
Figure 2
Table 3 -- Timing Characteristics
READ Cycle WRITE Cycle
Parameter
Pulse Width Data Delay Hold Time
Sym
TPW TD TD
Min
100 10
Max
50 -
Units
nsec nsec nsec
Parameter
Pulse Width Set-up Time Hold Time
Sym
TPW TS TH
Min
100 25 10
Max
-
Units
nsec nsec nsec
Table 4 -- Switch Data
Parameter
DC Continous Rated Current DC Trip Current (For Time to Trip Refer to Figure 3) On Resistance Output Leakage Current at 80 VDC Switch Turn-on Time Isolation
Sym
IC IOT RON IL TSD VISO
Min
1.1 600
Max
1 1.5 0.6 40 2 -
Units
Amps Amps Ohms A msec Volts
Aeroflex Circuit Technology
3
SCDCT2100 REV B 10/1/98 Plainview NY (516) 694-6700
Table 5 -- Bus Bit Definition
ADDRESS = 0 BIT D0 D1 D2 D3 D4 D5 D6 D7 WRITE CYCLE S1 ON/OFF 0 = ON Not Used S2 ON/OFF 0 = ON Not Used S3 ON/OFF 0 = ON Not Used S4 ON/OFF 0 = ON Not Used READ CYCLE S1 ON/OFF status (Bit = 0)(When switch on) S1 TRIP status (Bit = 1)(When short circuit protection active)) S2 ON/OFF Status S2 TRIP Status S3 ON/OFF Status S3 TRIP Status S4 ON/OFF Status S4 TRIP Status ADDRESS = 1 (Wrap Around) D0 - D7 Bit = 1 or 0 Whatever was written in the write cycle will be read ADDRESS = 2 D0 D1 D2 D3 D4 D5 D6 D7 X \1 X X X X X X X 0 = Command On (Signal being sent from the control side to Isolation Driver) Not Used 0 = Command On (Signal being sent from the control side to Isolation Driver) Not Used 0 = Command On (Signal being sent from the control side to Isolation Driver) Not Used 0 = Command On (Signal being sent from the control side to Isolation Driver) Not Used
\1 X = Don't care. During a write cycle (Address 2) it shall be considered as if the INIT is enabled.
Table 6 --Built-in Test Status (BIT)
Switch Control (Closed/OPEN)
1 0 0
TRIP Status
0 0 1
ON/OFF Status
1 0 1
Conclusion
Normal (OFF) Normal (ON) Switch Tripped off due to excessive load current
Note: All other TRIP and ON/OFF status combinations are indicative of switch, BIT or load failures
Aeroflex Circuit Technology
4
SCDCT2100 REV B 10/1/98 Plainview NY (516) 694-6700
Table 7A - Pin Numbers & Functions CT2100-400
Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Function VEE CS INIT DB0 DB1 PRESET/CLEAR 1 PRESET/CLEAR 2 DB2 DB3 VEE RETURN VCCRETURN DB4 DB5 PRESET/CLEAR 3 PRESET/CLEAR 4 DB6 DB7 WRITE READ VCC Pin # 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Function S4S4+ NC NC NC A1 A0 NC S3S3+ S2S2+ NC NC NC NC NC NC S1S1+
Table 7B -- Model CT2100-400 Dual In Line Package
TOP VIEW .120 .010
.120 .010 40
21 1.140 .010 .900 .010
Pin numbers are for reference only
1
20
2.140 .010 .180 .010 .016 .020 1.900 .005
5
.300 MAX
.100 TYP
Aeroflex Circuit Technology
SCDCT2100 REV B 10/1/98 Plainview NY (516) 694-6700
CIRCUIT TECHNOLOGY
Figure 3 -- Nominal Time to Trip Curve
3400 3200 3000 2800 2600 2400 2200 2000 1800 1600 1400 1200
1.1 Amps
Trip Envelope Range
Trip Region
No Trip Region
1000 800 600 1 10 100 1000
Time (ms)
Ordering Information
Model No.
CT2100-400
Specifications subject to change without notice.
Aeroflex Circuit Technology 35 South Service Road Plainview New York 11830
Aeroflex Circuit Technology 6
Telephone: (516) 694-6700 FAX: (516) 694-6715 Toll Free Inquiries: 1-(800) 843-1553
SCDCT2100 REV B 10/1/98 Plainview NY (516) 694-6700


▲Up To Search▲   

 